Search Plan Review Steps
| Name | Type | Length | Description |
|---|---|---|---|
| projectID | System.String | 20 | [Required] |
POST http://localhost/FusionServices/v3/Naviline/EPR/SearchPlanReviewSteps
| Name | Description |
|---|---|
| ErrorCode | Error Code |
| ErrorMessage | Error Message |
| TrkRevNumber | Tracking Revision Number |
| ApplTrkPath | Application Tracking Path |
| ApplTrkStep | Applicaiton Tracking Step |
| AgencyCode | Agency Code |
| StepSeqNumber | Step Sequence Number |
| DateIn | Date In (CCYYMMDD) |
| DateDue | Date Due (CCYYMMDD) |
| DateOut | Date OUt (CCYYMMDD) |
| ActualApprCode | Actual Approval Code |
| ReviewedByCode | Reviewed By Code |
| ReqdStepFlag | Required Step Flag (Y/N)> |
| ReqdApprCode | Required Approval Code |
| Error Code | Error Message |
|---|---|
| 0000 | Success |
| 0001 | Project number not found |
using System.Net;
using Newtonsoft.Json.Linq;
public void MethodName(parms)
{
string uri = "http://localhost/FusionServices/v3/Naviline/EPR/SearchPlanReviewSteps";
System.Collections.Specialized.NameValueCollection postParms =
new System.Collections.Specialized.NameValueCollection();
// Set paramater values
postParms.Add("projectID",System.Web.HttpUtility.UrlEncode("2200198"));
WebClient req = new WebClient();
wc.Headers.Add("Content-Type", "application/x-www-form-urlencoded");
wc.Headers.Set("X-APPID", "YOURID");
wc.Headers.Set("X-APPKEY", "YOURKEY");
byte[] responseBytes = wc.UploadValues(new Uri(uri), "POST", postParms);
string stringResult = Encoding.UTF8.GetString(responseBytes);
JObject response = JObject.Parse(stringResult);
string error = response["OutputParms"]["ErrorCode"].ToString();
if (error == "0000")
{
JArray jRows = (JArray)response["Rows"];
foreach (JObject row in jRows)
{
string TrkRevNumber = row["TrkRevNumber"].ToString();
string ApplTrkPath = row["ApplTrkPath"].ToString();
string ApplTrkStep = row["ApplTrkStep"].ToString();
string AgencyCode = row["AgencyCode"].ToString();
string StepSeqNumber = row["StepSeqNumber"].ToString();
string DateIn = row["DateIn"].ToString();
string DateDue = row["DateDue"].ToString();
string DateOut = row["DateOut"].ToString();
string ActualApprCode = row["ActualApprCode"].ToString();
string ReviewedByCode = row["ReviewedByCode"].ToString();
string ReqdStepFlag = row["ReqdStepFlag"].ToString();
string ReqdApprCode = row["ReqdApprCode"].ToString();
// TODO - YOUR CODE HERE
}
}
}
using System;
using System.Linq;
using System.Web;
using System.ComponentModel.DataAnnotations;
using System.Collections.Specialized;
using FusionServiceHelper.Models;
// NOTE: Use the namespace generated when you add the class, so that it is correct.
namespace FusionRazor.Models
{
public class PostSearchPlanReviewSteps
{
// Add property for each input param in order to map a field to it
[Required(ErrorMessage = "Required")]
[RegularExpression("^(?=.{0,20}$).*", ErrorMessage = "Must be 20 characters or less. ")]
public string projectID{get; set;}
public PostSearchPlanReviewSteps()
{
//Set any defaults here
}
}
}
@* NOTE: Use Add->View to add the View. *@
@* NOTE: Check the 'Create strongly-typed view checkbox, and select the PostSearchPlanReviewSteps class. *@
@* NOTE: Select Edit as the Scaffold template. *@
@* NOTE: Use the @model line that is generated at the top. Replace the rest with the lines below.
@model FusionRazor.Models.PostSearchPlanReviewSteps
@{
ViewBag.Title = "PostSearchPlanReviewSteps";
}
<h2>PostSearchPlanReviewSteps</h2>
@using (Html.BeginForm()) {
@Html.AntiForgeryToken()
@Html.ValidationSummary(true)
<fieldset>
<legend>PostSearchPlanReviewSteps</legend>
<div class="editor-label">
@Html.LabelFor(model => model.projectID)
</div>
<div class="editor-field">
@Html.EditorFor(model => model.projectID)
@Html.ValidationMessageFor(model => model.projectID)
</div>
<p>
<input type="submit" value="Submit"/>
</p>
</fieldset>
}
@section Scripts {
@Scripts.Render("~/bundles/jqueryval")
}
using System;
using System.Collections.Specialized;
using System.Linq;
using System.Web;
using System.Web.Mvc;
using FusionServiceHelper.Models;
// NOTE: Replace 'MyController' with the name of your controller.
//
// GET: /MyController/PostSearchPlanReviewSteps
public ActionResult PostSearchPlanReviewSteps()
{
// Create a new instance of the model to pick up any default values.
PostSearchPlanReviewSteps model = new PostSearchPlanReviewSteps();
// pass model to set to default values
// NOTE: Change 'MyFolderPath' to the path to the .cshtml file.
return View("~/Views/MyFolderPath/PostSearchPlanReviewSteps.cshtml", model);
}
//
// POST: /MyController/PostSearchPlanReviewSteps
[HttpPost]
public ActionResult PostSearchPlanReviewSteps(FormCollection collection)
{
string url = "v3/Naviline/EPR/SearchPlanReviewSteps";
// Get the value from each input field
NameValueCollection inputParms = new NameValueCollection();
inputParms.Add("projectID", collection["projectID"]);
try
{
// Send the request
FusionServiceRequest request = new FusionServiceRequest();
FusionServiceResult result = request.Post(url, inputParms);
return View("Result", result);
}
catch(Exception e)
{
HandleErrorInfo info = new HandleErrorInfo(e, "MyController", "PostSearchPlanReviewSteps");
return View("Error", info);
}
}