Get Inspection Details
Example: GET http://localhost/FusionServices/v3/Naviline/Inspection/GetInspectionDetails/09/500/000/000/BLDG/00/PL01/0001
| Name | Type | Length | Description |
|---|---|---|---|
| applicationYear | numeric | 2 | [Required] Two digit Application Year - if a 4 digit year is provided, only the last two digits are used |
| applicationNumber | numeric | 8 | [Required] Application Number |
| startNumber | numeric | 3 | [Required] Start Number. For a permit, Ex: 000 000 BLDG 01, this is the first set of three numbers. |
| startSequence | numeric | 3 | [Required] Start Sequence. For a permit, Ex: 000 000 BLDG 01, this is the second set of three numbers. |
| permitType | System.String | 4 | [Required] Permit Type. For a permit, Ex: 000 000 BLDG 01, this is the third set of four characters, which has to be one of the permit type codes. |
| permitSequence | numeric | 2 | [Required] Permit Sequence. For a permit, Ex: 000 000 BLDG 01, this is the fourth set of two numbers. |
| inspectionType | System.String | 4 | [Required] Inspection Type. 4 char code. Ex. BL02 |
| inspectionSequence | numeric | 4 | [Required] Inspection Sequence. 4 digit number indicating which inpection, if multiple were scheduled. |
GET http://localhost/FusionServices/v3/Naviline/Inspection/GetInspectionDetails/{applicationYear}/{applicationNumber}/{startNumber}/{startSequence}/{permitType}/{permitSequence}/{inspectionType}/{inspectionSequence}
| Name | Description |
|---|---|
| InspComment | Comment added to inspection |
| CommentCode | Q/R Q=Request comment R=Result comment |
| PermitDesc | Permit Description |
| InspectorName | Inspector Name |
| ScheduleDate | Date inspection was scheduled |
using System.Net;
using Newtonsoft.Json.Linq;
public void MethodName(parms)
{
string uri = "http://localhost/FusionServices/v3/Naviline/Inspection/GetInspectionDetails/09/500/000/000/BLDG/00/PL01/0001";
WebClient wc = new WebClient();
wc.Headers.Set("X-APPID", "YOURID");
wc.Headers.Set("X-APPKEY", "YOURKEY");
string stringResult = wc.DownloadString(new Uri(uri));
JObject response = JObject.Parse(stringResult);
string error = response["OutputParms"]["ErrorCode"].ToString();
if (error == "0000")
{
JArray jRows = (JArray)response["Rows"];
foreach (JObject row in jRows)
{
string InspComment = row["InspComment"].ToString();
string CommentCode = row["CommentCode"].ToString();
// TODO - YOUR CODE HERE
}
}
}
$.get('http://localhost/FusionServices/v3/Naviline/Inspection/GetInspectionDetails/09/500/000/000/BLDG/00/PL01/0001', function(response) {
$('#resultDiv).html(response);
});
using System;
using System.Linq;
using System.Web;
using System.ComponentModel.DataAnnotations;
using System.Collections.Specialized;
using FusionServiceHelper.Models;
// NOTE: Use the namespace generated when you add the class, so that it is correct.
namespace FusionRazor.Models
{
public class GetInspectionDetails
{
// Add property for each input param in order to map a field to it
[Required(ErrorMessage = "Required")]
[RegularExpression("[0-9]{0,2}", ErrorMessage = "Numeric values only. Must be 2 digits or less. ")]
public string applicationYear{get; set;}
[Required(ErrorMessage = "Required")]
[RegularExpression("[0-9]{0,8}", ErrorMessage = "Numeric values only. Must be 8 digits or less. ")]
public string applicationNumber{get; set;}
[Required(ErrorMessage = "Required")]
[RegularExpression("[0-9]{0,3}", ErrorMessage = "Numeric values only. Must be 3 digits or less. ")]
public string startNumber{get; set;}
[Required(ErrorMessage = "Required")]
[RegularExpression("[0-9]{0,3}", ErrorMessage = "Numeric values only. Must be 3 digits or less. ")]
public string startSequence{get; set;}
[Required(ErrorMessage = "Required")]
[RegularExpression("^(?=.{0,4}$).*", ErrorMessage = "Must be 4 characters or less. ")]
public string permitType{get; set;}
[Required(ErrorMessage = "Required")]
[RegularExpression("[0-9]{0,2}", ErrorMessage = "Numeric values only. Must be 2 digits or less. ")]
public string permitSequence{get; set;}
[Required(ErrorMessage = "Required")]
[RegularExpression("^(?=.{0,4}$).*", ErrorMessage = "Must be 4 characters or less. ")]
public string inspectionType{get; set;}
[Required(ErrorMessage = "Required")]
[RegularExpression("[0-9]{0,4}", ErrorMessage = "Numeric values only. Must be 4 digits or less. ")]
public string inspectionSequence{get; set;}
public GetInspectionDetails()
{
//Set any defaults here
applicationYear = DefaultData.Get("applicationYear");
applicationNumber = DefaultData.Get("applicationNumber");
startNumber = DefaultData.Get("startNumber");
startSequence = DefaultData.Get("startSequence");
permitType = DefaultData.Get("permitType");
permitSequence = DefaultData.Get("permitSequence");
inspectionType = DefaultData.Get("inspectionType");
inspectionSequence = DefaultData.Get("inspectionSequence");
}
}
}
@* NOTE: Use Add->View to add the View. *@
@* NOTE: Check the 'Create strongly-typed view checkbox, and select the GetInspectionDetails class. *@
@* NOTE: Select Edit as the Scaffold template. *@
@* NOTE: Use the @model line that is generated at the top. Replace the rest with the lines below.
@model FusionRazor.Models.GetInspectionDetails
@{
ViewBag.Title = "GetInspectionDetails";
string myUrl = "http://localhost/FusionServices/v3/Naviline/Inspection/GetInspectionDetails/" + Model.applicationYear + "/" + Model.applicationNumber + "/" + Model.startNumber + "/" + Model.startSequence + "/" + Model.permitType + "/" + Model.permitSequence + "/" + Model.inspectionType + "/" + Model.inspectionSequence;
}
<h2>GetInspectionDetails</h2>
@using (Html.BeginForm()) {
@Html.AntiForgeryToken()
@Html.ValidationSummary(true)
<fieldset>
<legend>GetInspectionDetails</legend>
<div class="editor-label">Use the fields below to change the values and resubmit.</div>
<div class="editor-label">
@Html.LabelFor(model => model.applicationYear)
</div>
<div class="editor-field">
@Html.EditorFor(model => model.applicationYear)
@Html.ValidationMessageFor(model => model.applicationYear)
</div>
<div class="editor-label">
@Html.LabelFor(model => model.applicationNumber)
</div>
<div class="editor-field">
@Html.EditorFor(model => model.applicationNumber)
@Html.ValidationMessageFor(model => model.applicationNumber)
</div>
<div class="editor-label">
@Html.LabelFor(model => model.startNumber)
</div>
<div class="editor-field">
@Html.EditorFor(model => model.startNumber)
@Html.ValidationMessageFor(model => model.startNumber)
</div>
<div class="editor-label">
@Html.LabelFor(model => model.startSequence)
</div>
<div class="editor-field">
@Html.EditorFor(model => model.startSequence)
@Html.ValidationMessageFor(model => model.startSequence)
</div>
<div class="editor-label">
@Html.LabelFor(model => model.permitType)
</div>
<div class="editor-field">
@Html.EditorFor(model => model.permitType)
@Html.ValidationMessageFor(model => model.permitType)
</div>
<div class="editor-label">
@Html.LabelFor(model => model.permitSequence)
</div>
<div class="editor-field">
@Html.EditorFor(model => model.permitSequence)
@Html.ValidationMessageFor(model => model.permitSequence)
</div>
<div class="editor-label">
@Html.LabelFor(model => model.inspectionType)
</div>
<div class="editor-field">
@Html.EditorFor(model => model.inspectionType)
@Html.ValidationMessageFor(model => model.inspectionType)
</div>
<div class="editor-label">
@Html.LabelFor(model => model.inspectionSequence)
</div>
<div class="editor-field">
@Html.EditorFor(model => model.inspectionSequence)
@Html.ValidationMessageFor(model => model.inspectionSequence)
</div>
<p>
<input type="submit" value="Submit"/>
</p>
</fieldset>
}
@section Scripts {
@Scripts.Render("~/bundles/jqueryval")
}
using System;
using System.Collections.Specialized;
using System.Linq;
using System.Web;
using System.Web.Mvc;
using FusionServiceHelper.Models;
// NOTE: Replace 'MyController' with the name of your controller.
//
// GET: /MyController/GetInspectionDetails
public ActionResult GetInspectionDetails()
{
// Create a new instance of the model to pick up any default values.
GetInspectionDetails model = new GetInspectionDetails();
// pass model to set to default values
// NOTE: Change 'MyFolderPath' to the path to the .cshtml file.
return View("~/Views/MyFolderPath/GetInspectionDetails.cshtml", model);
}
//
// POST: /MyController/GetInspectionDetails
[HttpPost]
public ActionResult GetInspectionDetails(FormCollection collection)
{
string url = "v3/Naviline/Inspection/GetInspectionDetails/{applicationYear}/{applicationNumber}/{startNumber}/{startSequence}/{permitType}/{permitSequence}/{inspectionType}/{inspectionSequence}";
// Get the value from each input field
NameValueCollection inputParms = new NameValueCollection();
inputParms.Add("applicationYear", collection["applicationYear"]);
inputParms.Add("applicationNumber", collection["applicationNumber"]);
inputParms.Add("startNumber", collection["startNumber"]);
inputParms.Add("startSequence", collection["startSequence"]);
inputParms.Add("permitType", collection["permitType"]);
inputParms.Add("permitSequence", collection["permitSequence"]);
inputParms.Add("inspectionType", collection["inspectionType"]);
inputParms.Add("inspectionSequence", collection["inspectionSequence"]);
try
{
// Send the request
FusionServiceRequest request = new FusionServiceRequest();
FusionServiceResult result = request.Get(url, inputParms);
return View("Result", result);
}
catch(Exception e)
{
HandleErrorInfo info = new HandleErrorInfo(e, "MyController", "GetInspectionDetails");
return View("Error", info);
}
}